Skip to content

SP Dynamis

ER:YAG + ND:YAG LASER PLATFORM

  • 2 lasers: Er:YAG 2940 nm + Nd:YAG 1064 nm
  • SMOOTH, TightSculpting and Fotona 4D protocols
  • Face, body and aesthetic gynaecology
Price on request

Professional device for clinics

22-year warranty
Purchase options
  • cash / transfer
  • leasing
  • instalment loan

SKU: FOTONA-SP-DYNAMIS Categories: Multi-platform systems · Fotona

Fill in the form and get an offer

The data controller is Future by Life sp. z o.o.. We process data to respond to your enquiry (Art. 6(1)(b) and (f) GDPR). You have the right of access, rectification, erasure, restriction, portability, objection and to lodge a complaint with the supervisory authority (UODO).

SP Dynamis

Er:YAG/Nd:YAG platform for 4D rejuvenation, resurfacing, vessels, hair removal and aesthetic gynaecology.

Kit
  • SP Dynamis main unit
  • Er:YAG articulated arm with a basic handpiece set
  • Nd:YAG fibre with handpiece
  • Scanner / additional handpieces – per selected configuration
  • Footswitch
  • Protective eyewear for operator and patient, rated for 2940 i 1064 nm
  • User manual in Polish
  • Hands-on operator training and personal Future Life certificate

Certification

Device compliant with EU requirements

Professional device for clinics

  • · CE marking (EU medical device) – class per manufacturer EU DoC
  • · IEC 60825-1 Class 4 laser product

Support

Comprehensive after-sales care

On-site training, training and marketing materials, warranty and post-warranty service.

  • · Certified onboarding training included
  • · 2-year warranty
  • · In-house service centre, inspections, loan device

Treatments

New treatments for your clinic

  • · Fotona 4D facial rejuvenation
  • · Ablative and fractional resurfacing (wrinkles, acne scars)
  • · Vascular lesions and redness
  • · Nd:YAG laser hair removal
  • · Body skin tightening (TightSculpting)
  • · Aesthetic gynaecology (SMOOTH protocols)
  • · Removal of benign skin lesions (warts, skin tags)

Fotona

Two complementary wavelengths

Er:YAG 2940 nm is strongly absorbed by water and acts superficially with precise control of ablation depth. Nd:YAG 1064 nm penetrates deeply and heats the dermis. Combining both in one system lets you work from the epidermis to deeper tissue layers.

VSP pulse control

Variable Square Pulse technology allows precise shaping of pulse energy and duration. The same laser can thus act ablatively or purely thermally, depending on the selected mode and indication.

Fotona 4D and SMOOTH

The platform supports established Fotona protocols, including four-step 4D facial rejuvenation and the non-ablative SMOOTH mode based on thermal tissue stimulation. These are recognisable treatment brands that make your offer easier to communicate.

One device – many specialities

Dermatology, aesthetic medicine, aesthetic gynaecology and skin surgery – SP Dynamis lets you grow new service lines without buying separate lasers. An attractive solution for multi-specialty clinics.

Technical data

Technology
Er:YAG + Nd:YAG multi-application platform (SMOOTH, TightSculpting, 4D)
Wavelengths
2940nm + 1064nm
Laser source
Er:YAG 2940 nm + Nd:YAG 1064 nm

Kit contents

  • SP Dynamis main unit
  • Er:YAG articulated arm with a basic handpiece set
  • Nd:YAG fibre with handpiece
  • Scanner / additional handpieces – per selected configuration
  • Footswitch
  • Protective eyewear for operator and patient, rated for 2940 i 1064 nm
  • User manual in Polish
  • Hands-on operator training and personal Future Life certificate

Training for this device

Advanced User of Diode and Hybrid LasersAn original course by Dr Elena Tkach, cosmetologist, for laser hair-removal specialistsGet the course programme

Questions & answers

Who can perform treatments with SP Dynamis?

Ablative, surgical and gynaecological procedures should be performed by an appropriately qualified physician. Some non-ablative procedures may be performed by trained staff under medical supervision, in line with applicable law and the manufacturer's IFU.

What is downtime like?

It depends on the mode: non-ablative procedures (e.g. SMOOTH) usually involve short, transient redness, while ablative resurfacing requires several days of healing. Details should be discussed with the patient during consultation.

What are the main contraindications?

Typical contraindications include pregnancy, active infection or inflammation in the treatment area, a fresh tan or self-tanner, photosensitising medication (e.g. isotretinoin), a tendency to keloid scarring and suspicious lesions at the treatment site. The full list is in the manufacturer's IFU – we recommend a consultation and a test spot before the first session.

Does Future Life provide training?

Yes. At installation we deliver hands-on training covering device operation, safety rules and the manufacturer's treatment protocols for the selected protocols. Participants receive a personal Future Life certificate, and new team members can be trained at a later date.

Similar products