Skip to content

GentleMax Pro Plus

ALEXANDRITE + ND:YAG LASER

  • 2 lasers: 755 nm alexandrite + 1064 nm Nd:YAG
  • Spot up to 26 mm · up to 10 Hz
  • DCD cryogen cooling
Price on request

Professional device for clinics

22-year warranty
Purchase options
  • cash / transfer
  • leasing
  • instalment loan

SKU: CANDELA-GENTLEMAX-PRO-PL Categories: Alexandrite & Nd:YAG (hybrid) lasers · Candela

Fill in the form and get an offer

The data controller is Future by Life sp. z o.o.. We process data to respond to your enquiry (Art. 6(1)(b) and (f) GDPR). You have the right of access, rectification, erasure, restriction, portability, objection and to lodge a complaint with the supervisory authority (UODO).

GentleMax Pro Plus

Gold-standard hair removal – 755 nm alexandrite and 1064 nm Nd:YAG with DCD cryogen cooling.

Kit
  • GentleMax Pro Plus main unit
  • Fibre delivery handpiece with a set of spot sizes
  • DCD cooling system with cryogen canister
  • Footswitch
  • Protective eyewear for operator and patient, rated for 755 i 1064 nm
  • Safety key and remote door interlock connector
  • User manual in Polish
  • Hands-on operator training and personal Future Life certificate

Certification

Device compliant with EU requirements

Professional device for clinics

  • · CE marking (EU medical device) – class per manufacturer EU DoC
  • · IEC 60825-1 Class 4 laser product
  • · FDA 510(k) cleared (US)

Support

Comprehensive after-sales care

On-site training, training and marketing materials, warranty and post-warranty service.

  • · Certified onboarding training included
  • · 2-year warranty
  • · In-house service centre, inspections, loan device

Treatments

New treatments for your clinic

  • · Facial hair reduction (upper lip, chin, cheeks)
  • · Underarm hair removal
  • · Hair removal on legs and large body areas
  • · Bikini line and intimate area hair removal
  • · Benign pigmented lesions (lentigines, sun spots)
  • · Vascular lesions: telangiectasia and leg veins
  • · Wrinkles and skin rejuvenation (1064 nm, per manufacturer protocols)

Candela

Two lasers in one platform

The 755 nm alexandrite offers high melanin absorption and suits lighter skin and finer hair. The 1064 nm Nd:YAG penetrates deeper and is less absorbed by the epidermis, extending treatment to darker skin types. Switching takes a single button press.

DCD cryogen cooling

The Dynamic Cooling Device releases a brief cryogen spray just before each laser pulse. It cools the epidermis without handpiece contact, supporting patient comfort and skin protection at higher fluences.

Large spot and short pulses

A spot of up to 26 mm and repetition rates up to 10 Hz speed up treatments on the back or legs. A short-pulse mode from 2 ms supports work on fine hair, and according to the manufacturer fluence is higher than in the previous GentleMax Pro generation.

Versatility beyond hair removal

The same platform supports treatment of benign pigmented and vascular lesions as well as skin rejuvenation. A broader menu means better daily utilisation of the device.

Technical data

Technology
Long-pulse Alexandrite + Nd:YAG dual-wavelength laser
Wavelengths
755nm + 1064nm
Spot size
up to 26 mm (large-spot delivery); standard 6–18 mm
Pulse duration
from 2 ms (short-pulse mode for fine hair)
Repetition rate
up to 10 Hz
Cooling
Dynamic Cooling Device (DCD) cryogen spray
Fluence
up to 38% higher than GentleMax Pro (manufacturer claim)

Kit contents

  • GentleMax Pro Plus main unit
  • Fibre delivery handpiece with a set of spot sizes
  • DCD cooling system with cryogen canister
  • Footswitch
  • Protective eyewear for operator and patient, rated for 755 i 1064 nm
  • Safety key and remote door interlock connector
  • User manual in Polish
  • Hands-on operator training and personal Future Life certificate

Training for this device

Advanced User of Diode and Hybrid LasersAn original course by Dr Elena Tkach, cosmetologist, for laser hair-removal specialistsGet the course programme

Parts & accessories

Questions & answers

When should I choose 755 nm vs 1064 nm?

755 nm is typically used for lighter skin types (approx. I–III/IV) and finer hair, whereas 1064 nm is preferred for darker and tanned skin and deeper follicles. The final choice depends on skin assessment and a test spot.

What are the consumables?

The main consumable is cryogen for the DCD system; consumption depends on the number and size of treated areas. Periodic service inspections per the manufacturer's schedule are also required – Future Life supplies cryogen and provides service.

What are the main contraindications?

Typical contraindications include pregnancy, active infection or inflammation in the treatment area, a fresh tan or self-tanner, photosensitising medication (e.g. isotretinoin), a tendency to keloid scarring and suspicious lesions at the treatment site. The full list is in the manufacturer's IFU – we recommend a consultation and a test spot before the first session.